Context
Academic — TUM Practical Course, Experimental Fluid Dynamics
Role
Experimentalist
Stack
Constant-Temperature Anemometry (CTA), traverse rig, Python
Pipe-flow boundary layers & mesh pressure-drop poster — hot-wire CTA measurements
Case study poster — Pipe-flow boundary layers & mesh pressure-drop (TUM, 2024)

Problem

Two distinct but related questions driven from first principles. First, how does a pipe-flow boundary layer develop along the entrance region, and at what streamwise station does the velocity profile stop evolving — i.e., become fully developed? Second, how much pressure is lost across wire-mesh screens of different spacing densities, and how does that loss depend on approach velocity and mesh open-area ratio? Both are classical problems with well-known correlations, which made them ideal for learning how to design, run, and defend an experiment against theory rather than trusting either blindly.

Approach

  • Pipe-flow rig — instrumented pipe with an inlet contraction and a traversable hot-wire probe; Reynolds numbers covering the laminar-to-turbulent transition range.
  • CTA calibration — calibrated the hot-wire against a Pitot reference using a King's Law fit (E² = A + B·Un) before every measurement campaign, to keep drift out of the profile data.
  • Radial traverses — took radial velocity profiles at multiple streamwise stations from x/D ≈ 5 to x/D ≈ 60, resolving the wall region with fine near-wall steps.
  • Entrance-length diagnostics — tracked the centreline-velocity evolution and the profile shape (laminar → parabolic, turbulent → power-law) against x/D to pin the development length.
  • Mesh pressure-drop sweep — characterised three mesh densities at a range of approach velocities, recording ΔP with a differential manometer and comparing against Idelchik/Wieghardt correlations for screen loss.
Overview of pipe flow boundary layer results — velocity profiles, Reynolds numbers, and mesh comparisons
Results overview — boundary layer velocity profiles at different streamwise stations (x/D), mean Reynolds numbers, and normalized profiles for coarse/medium/fine mesh cases.
Pipe flow test bench — contraction, CTA traverse, cRIO acquisition, and flow conditioning inserts
Experimental setup — pipe flow testbench with inlet contraction, CTA hot-wire traverse, cRIO data acquisition, and interchangeable mesh inserts (coarse/medium/fine).
Schematic of hydrodynamic entrance region — uniform inlet flow developing into fully developed parabolic profile
Entrance region schematic — uniform inlet velocity profile evolves through boundary layer growth into fully developed parabolic laminar flow.
Dimensionless entrance length vs Reynolds number — laminar and turbulent regimes with empirical correlations
Entrance length theory — dimensionless entrance length (Le/D) vs Reynolds number. Laminar: Le/D ≈ 0.0575·Re. Turbulent: Le/D ≈ 4.4·Re^(1/6). Hot-wire probe placed at x/D = 148.7 to ensure fully developed flow.
King's Law calibration for hot-wire anemometer — voltage squared vs velocity with pipe velocity range highlighted
King's Law calibration — V² = A + B·uⁿ fit (A=8.871, B=3.856, n=0.448). Green shaded region marks pipe velocity range (0.015–12.67 m/s).
Velocity profile validation — experimental vs analytical laminar (Hagen-Poiseuille) and turbulent (power law) profiles
Velocity profile validation — experimental data vs analytical models. Laminar: Hagen-Poiseuille parabolic profile. Turbulent: power law with n=0.1, 0.2, 0.33. Deviations near top wall caused by measurement port disturbance.
Skin friction coefficient vs Reynolds number — experimental data vs Blasius correlation
Skin friction coefficient — experimental λ vs Blasius correlation (λ = 0.3164/Re^0.25). Deviations at high Re indicate roughness effects or transition regime.
Pressure loss coefficient across mesh installations — loss coefficient vs Reynolds number for different mesh densities
Pressure loss coefficient — ζ vs Reynolds number for no screen (NS), coarse (AR), medium (MS), fine (FS), and staggered (CS) meshes. Higher mesh density produces greater pressure loss. Loss coefficient becomes Re-independent above Re ≈ 15,000.

Tools & setup

  • CTA hot-wire — single-wire probe on a motorised traverse, King's-Law calibrated per campaign.
  • Differential manometer — static-pressure taps upstream and downstream of each mesh screen.
  • Python — profile fitting (Power-Law turbulent + Blasius-flat-plate comparisons), friction-factor extraction from pressure-drop vs velocity slopes, uncertainty propagation from calibration residuals.

Results

  • Entrance length — fully-developed turbulent flow reached within the range predicted by the classical Le/D ≈ 4.4·Re1/6 correlation. Laminar-regime points matched the Langhaar Le/D ≈ 0.06·Re estimate within experimental scatter.
  • Fully-developed profile — the 1/n power-law fit to turbulent profiles gave n values increasing from ~6 at low Re to ~7–8 at higher Re, consistent with textbook behaviour.
  • Friction factor — measured λ agreed with the Blasius correlation (λ = 0.316·Re−1/4) within a few percent in the turbulent range after subtracting mesh loss.
  • Mesh loss — ΔP scaled quadratically with approach velocity for each mesh density, with loss coefficient K increasing monotonically as open-area ratio decreased — in line with Idelchik's screen-loss formulation.

The most instructive moment was the drift check: re-calibrating the hot-wire at mid-campaign showed a small but real upward drift in the King's-Law fit, which, if ignored, would have inflated measured velocities by a couple of percent. The calibration discipline was the lesson, not the velocity number.

Validation

The experiment was designed around validation: every measured quantity had a closed-form theoretical target — Langhaar/White for entrance length, Blasius / Colebrook for friction factor, Idelchik for screen loss — and the agreement (or disagreement) was the scientific product. Disagreements were traced, not absorbed: near-wall velocity underestimation at the smallest step came from probe-wall interference and was called out explicitly in the report.

Lessons learned

  • Hot-wire work is a calibration exercise first and a measurement exercise second. The King's-Law drift check was not optional; it was the experiment.
  • Entrance length is surprisingly long even at modest Re. Test-section instrumentation placed too close to the inlet gives profiles that look fully developed but aren't.
  • Screen-loss correlations like Idelchik's are blunt instruments, but they're the right blunt instrument. Matching the measured K to within ~10% with a one-parameter correlation is a fair result.

Artifacts

  • TUM practical course report — "Experimental Fluid Dynamics: pipe-flow development and mesh pressure drop".
  • Python data-reduction notebook (calibration fits, profile plots, loss coefficient extraction).